    產品簡介
    英文名:VitaminCinPlasma/Serum-HPLC供應商:祥生興業規格:100TestsVitaminCinPlasma/Serum-HPLCOrderno
    產品介紹

    溫馨提示:僅用于科研,不可用于臨床治療

    • 英文名:

      Vitamin C in Plasma/Serum - HPLC

    • 供應商:

      祥生興業

    • 規格:

      100 Tests

      Vitamin C in Plasma/Serum - HPLC


      Order no.: 65065
      100 Tests
      • Vitamin C

      Simplified sample preparation
      Enhanced column stability
      High stability of standards and controls

      DESCRIPTION

      Clinical relevance

      Vitamin C (ascorbic acid, ascorbate) is a water-soluble vitamin that is an essential cofactor for the human body, for instance in the catabolism of tyrosine and the synthesis of catecholamines. Regular consumption of fruit and vegetables is usually sufficient to cover the body’s vitamin C needs.

      In the case of vitamin C deficiency, procollagen chains are produced insufficiently and stable fibrils cannot be formed in the affected cells. Without functioning collagen, the blood vessels and tendons become fragile and the typical skin-related symptoms associated with scurvy start to develop. In addition to the collagen damages described above, further diseases caused by vitamin C deficiency include bleeding of uncertain origin, loss of teeth and overactive thyroid gland (hyperthyroidism). Vitamin C deficiency is also observed in dialysis patients, in chronic alcohol abuse and during pregnancy.

       

      Product advantages

      • High stability of processed samples and controls
      • Enhanced column stability
      • Reliable quantification with a stable internal standard

       

      This Chromsystems kit allows the reliable chromatographic determination of vitamin C in one isocratic HPLC run with UV detection. An efficient protein precipitation step removes interfering components and stabilises Vitamin C simultaneously. A stable internal standard is used for reliable quantification. Due to a special stabilisation of the prepared samples, it is also possible to reliably process and measure large sample batches.

       

       

      CHROMATOGRAM

      65065 HPLC kit vitamin C plasma serum - Chromatogramm EN

      TECHNICAL DATA

      Method of Analysis

      HPLC

      Number of Tests

      100

      Parameter

      Vitamin C

      Analysis Time

      5 min

      Limit of quantification

      0.4 mg/l

      Linearity

      0.4–100 mg/l

      Recovery

      97–103 %

      Intraassay

      CV ≤ 3.8 %

      Interassay

      CV ≤ 4.8 %

      Specimen

      Plasma/Serum

      Pre-analytic Treatment

      Fresh lithium heparin plasma is used for analysis. To minimise the oxidation of vitamin C the whole blood sample should be centrifuged immediately after collection and the plasma samples must then be transported deep frozen. Start sample preparation immediately after thawing. The stability for vitamin C in heparin plasma is 5 days at -20 °C. At room temperature this is only up to two hours. If whole blood is used for transportation, store at +2 to +8 °C , do not freeze.

      Sample Preparation

      • Pipette 100 μl sample/calibrator/control into a labelled light protected reaction vial.

      • Add 100 μl Internal Standard and mix 30 s (vortex).

      • Centrifuge 5 min at at least 13000 x g.

      • Inject 20 μl of the supernatant into the HPLC system.

      Sample Stability

      The patient samples are stable for 12 h at room temperatur, at +2 to +8 °C for at least 2 weeks. For longer storage (up to 6 weeks) keep samples below -18 °C.

      Additional Info

      Any isocratic HPLC system with UV detection is suitable.

       

      Injection Volume

      20 µl

      Flow rate

      1.5 ml/min

      Gradient

      Isocratic

      Column temperature

      ambient (~25 °C)

      Wavelength

      245 nm

      Please note

      The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals.

      KIT COMPONENTS

      Components available separately

      Mobile Phase


      Order no.: 65001

      DETAILS

      Mobile Phase, 10 x 1000ml


      Order no.: 65002

      DETAILS

      Internal Standard


      Order no.: 65044

      DETAILS

      Reaction vials


      Order no.: 33005

      DETAILS

      Vitamin C Plasma Calibration Standard


      Order no.: 65003

      DETAILS

      ACCESSORIES

      PEEK prefilter housing


      Order no.: 15010

      DETAILS

      HPLC column


      Order no.: 65100

      DETAILS

      PEEK-encased prefilter, 5 µm


      Order no.: 15009

      DETAILS

      Precolumn cartridge 4/10


      Order no.: 18065

      DETAILS

      Precolumn cartridge holder 4/10


      Order no.: 18001

      DETAILS

      CALIBRATORS

      Calibrators available separately

      Vitamin C Plasma Calibration Standard


      Order no.: 65003

      DETAILS

      CONTROLS

      Controls available separately

      Vitamin C Plasma Controls


       

      DETAILS

    溫馨提示:不可用于臨床治療。


    會員登錄

    ×

    請輸入賬號

    請輸入密碼

    =

    請輸驗證碼

    收藏該商鋪

    X
    該信息已收藏!
    標簽:
    保存成功

    (空格分隔,最多3個,單個標簽最多10個字符)

    常用:

    提示

    X
    您的留言已提交成功!我們將在第一時間回復您~
    產品對比 二維碼 在線交流

    掃一掃訪問手機商鋪

    對比框

    在線留言