亚洲欧美日韩精品,日本一区二区在线免费观看,全部无卡免费的毛片在线看,狠狠操av,成人国内精品久久久久影院,夜夜干夜夜,中文字幕人妻丝袜乱一区三区,国产ts在线视频专区
    湖南格雷柏電子科技有限公司
    中級會員 | 第4年

    18573116298

    當前位置:湖南格雷柏電子科技有限公司>>器件級靜電放電解決方案>>TLP傳輸線脈沖測試系統>> ES622-50ES622 Series TLP Pulsed IV-Curve System

    ES622 Series TLP Pulsed IV-Curve System

    參  考  價面議
    具體成交價以合同協議為準

    產品型號ES622-50

    品       牌ESDEMC

    廠商性質代理商

    所  在  地長沙市

    更新時間:2024-08-21 11:19:06瀏覽次數:2034次

    聯系我時,請告知來自 化工儀器網
    同類優質產品更多>
    應用領域 電子/電池,航空航天,汽車及零部件,電氣
    ES622 Series TLP Pulsed IV-Curve System is an advanced IV-curve characterization system designed to simulate ESD events (TLP/ VF-TLP/ HMM/ HBM/MM pulse) and monitor a device

    ES622 Series TLP Pulsed IV-Curve System


    1.    Description

    The model ES622 Series TLP Pulsed IV-Curve System is an advanced IV-curve characterization system designed to simulate ESD events (TLP/ VF-TLP/ HMM/ HBM/MM pulse) and monitor a device (semiconductors, discrete, circuit modules, etc.) in high power time domain. The ES622 has a higher specification, more functionality, greater expansion capability and better software experience compared to the previous model ES620 and ES621.

    The TLP (transmission line pulse) test function is designed to meet the latest ANSI/ESD STM5.5.1 test standard and applies high quality rectangular pulses to devices and records both the voltage across and current through the device. This gives pulsed IV curves, allowing users to characterize a device’s transient response over ns time windows. Advanced automatic device failure detection methods are incorporated, such as DC Spot Check (V or I), Static IV curve, Fuse, Breakdown, and Bias Source Fluctuation.

    The VF-TLP test is designed to simulate the CDM speed ESD event and captures the voltage across the DUT and current through the DUT under a high speed (such as <100 ps rise-time) ESD transient. This allows the user to study the response speed and peak clamping voltage of a device.

    The HMM (Human Metal Model) test function is an alternative test method to IEC61000-4-2 system level ESD. It gives the equivalent waveform to an ideal standard waveform for low ohm devices and eliminates many IEC gun test problems for components or wafer level tests, such as repeatability, imprecision gun tip, impedance mismatches, EMI interferences from unshielded relays and special setup with large ground plane and coupling plane etc.

    2.    Features

    • Most configurable TLP Pulsed IV-Curve System

    • Ultra-Compact Design System

    • Fast test speed with multi-thread processing

    • 20 A, 40A, 50 A, 100 A, 125A, 150 A models are available (Customization available)

    • Advanced system and accessory monitor and control in software available
      (switch lifespan monitor, E-Cal module, oscilloscope attenuation adjustment)

    • Test Function Expandable with vf-TLP, CC-TLP, HMM, HBM, MM options

    • Multiple automatic failure detection methods
      (DC spot check (V or I) or IV sweep, fuse, breakdown, and bias current change)

    • Software controlled pulsing: Burst, Continuous, IV-Curve Characterization

    • Rise-Time options from 40 ps to 1200 ns *(depends on model, customization available)

    • Pulse-Width options from 1 ns to 2000 ns *(depends on model, customization available)

    Note*: Longer pulse applications are supported by EOS series with pulse width from few hundred of ns to few ms.

    3.     Applications

    • ESD performance characterization

    • Wafer/ package level ESD test

    • System / circuit module ESD test

    • Safe operation area (SOA) test

    • Charge recovery time test

    • Solar panel diode characterization

    • Touchscreen ITO trace fuse and breakdown test

    Related Standards:

    • TLP / VF-TLP option meets ANSI/ESD STM 5.5.1

    • HMM option meets ANSI/ESD SP5.6

    • HBM option meets ANSI/ESDA/JEDEC JS-001

    • MM option meets ANSI/ESDA SP5.2

    4.    Specifications

    ES622 Series TLP Unit Specifications

    Typical Models ES622-20 ES622-50 ES622-100 ES622-125 ES622-150 Unit *Special models such as 40, 100, 200+ A are available per request
    Output voltage  @ Open load ± 0.5 ~ 1000 ± 0.5 ~ 2500 ± 0.5 ~ 5000 ± 0.5 ~ 6250 ± 0.5 ~ 7500 V  
    Min Voltage step @ Open load 0.1 0.1 0.1 0.1 0.1 V  
    Output current @ Short load ± 0.01 ~ 20 ± 0.01 ~ 50 ± 0.01 ~ 100 ± 0.01 ~ 125 ± 0.01 ~ 150 A  
    Voltage precision Accuracy adjustable between 1 – 10 % % Speed / accuracy software adjustable
    Fastest rise-time*
    (default 20-80%)
    ≤ 50 ≤ 200 ≤ 300 ≤ 300 ≤ 300 ps Fastest 10-90% 40 ps risetime is available with special configuration
    Rise-time range 0.05 ~ 1200 0.2 ~ 1200 0.3 ~ 1200 0.3 ~ 1200 0.3 ~ 1200 ns  
    Rise-time options Unlimited programable or manual options   per customization
    Pulse-width
    (default 50-50%)
    100 ± 1 ns Default
    Min Pulse-width 0.5 1 5 5 5 ns  
    Max Pulse-width 2000 2000 1500 1500 1000 ns  
    Pulse-width options Unlimited programable or manual options   per customization
    Test Speed Typical 0.2 ~ 2 Sec Varies between hardware setups
    Dimensions 347 W X 300 D X 145 H mm May change per customization
    Weight 8 8 8 10 12 kg  
    Supported Oscilloscopes Major Series from Tektronix, Agilent, LeCroy, Rigol. Others supported on request
    Supported SMU Keithley 24xx/26xx series SMU Others supported on request

    ES62X-HMM2 External Human Metal Model (HMM) Module
    (short circuit DUT, 100 ? HMM per ANSI/ESD SP5.6)

    @ Typical Models ES620-20 ES620-50 ES622-100 ES620-125 ES620-150 Unit Comments
    IEC equivalent level 6 12 24 30 36 kV  
    HMM peak current 22.5 45 90 112.5 135 A 3.75 A per 1 kV ≤ ± 10 %

     

    IEC 61000-4-2 (R=330?, C=150pF)

    HMM current @ 30 ns 12 24 48 60 72 A ≤ ± 10 % (better than ±30% IEC)
    HMM current @ 60 ns 6 12 24 30 36 A ≤ ± 10 % (better than ±30% IEC)

    ES62X-HBM2 External Human Body Model (HBM) Module
    (ANSI/ESDA/JEDEC JS-001 R=1.5 k?, C=100 pF)

    @ Typical Models ES620-20 ES620-50 ES622-100 ES620-125 ES620-150 Unit Comments
    Maximum HBM Test Level ± 2 ± 4 ± 8 ± 10 ± 12 kV  
    Minimum HBM Test Level ± 50 V  
    Minimum Test Level Step 1 V PCB controlled via USB
    Charge Removal Resistance 10 K Ohm  
    Test Speed >= 1 S Per Standard 1P/S
    Physical Dimensions 90 X 90 X 130 mm  

    ES62X-MM2 External Machine Model (MM) Module
    (ANSI/ESDA/JEDEC JS-001 R=1.5 k?, C=100 pF)

    Parameters MM-2K Unit Comments
    Output Voltage ±10 ~ 2000 V  
    Discharge RC Value C: 200 pF, R: 0 Ω    
    Short Load Peak Current Ip1 1.75±10% per 100V A Tolerance may be different if socket is used
    Short Load Ip2 67% ~ 90% of Ip1 A
    Short Load Pulse Period tpm 66 < tpm < 90 ns
    500 Ω Load Peak Current Ipr 0.85 ~ 1.2 A @ 400 V condition per standard
    500 Ω Load I100 0.23 ~ 0.4 A @ 400 V condition per standard
    500 Ω Load I200 30 – 50% of measured I100 A  

    5.    Ordering Information

    Line Part # or Option # Description
    TLP IV-Curve System Basic Configuration
    1.1 ES622-20 ES622 TLP Pulsed IV-Curve System, 20 A Base Unit
    1.2 ES622-25 ES622 TLP Pulsed IV-Curve System, 25 A Base Unit
    1.3 ES622-40 ES622 TLP Pulsed IV-Curve System, 40 A Base Unit
    1.4 ES622-50 ES622 TLP Pulsed IV-Curve System, 50 A Base Unit
    1.5 ES622-60 ES622 TLP Pulsed IV-Curve System, 50 A Base Unit
    1.6 ES622-80 ES622 TLP Pulsed IV-Curve System, 80 A Base Unit
    1.7 ES622-100 ES622 TLP Pulsed IV-Curve System, 100 A Base Unit
    1.8 ES622-125 ES622 TLP Pulsed IV-Curve System, 125 A Base Unit
    1.9 ES622-150 ES622 TLP Pulsed IV-Curve System, 150 A Base Unit
    Rise-time Options (example configuration only, customizable option available)
    2.1 ES62x-PRT4 Programmable pulse rise-time filter X4 module
    (Default:   Intrinsic, 1 ns, 5 ns, 10 ns, customization available)
    2.2 ES62x-PRT7 Programmable pulse rise-time filter X7 module
    (Default:   Intrinsic, 0.5ns, 1 ns, 2ns, 5 ns, 10 ns, 20ns, customization available)
    2.3 ES62x-ERTF External Manual Rise-time Filter
    Pulse-width Options (example configuration only, customizable option available)
    3.1 ES620-PPL4 ProgrammableInternal pulse length X4 module
    (Default:   5ns, 10 ns, 100 ns, 200 ns, customization available)
      ES620-PPL7 ProgrammableInternal pulse length X7 module
    (Default:   5ns, 10 ns, 50ns, 100 ns, 200 ns, 500ns, 1000ns, customization available)
    3.2 ES620-PPL10 ProgrammableInternal pulse length X10 module
    (Default:   2ns, 5ns, 10 ns, 20ns, 50ns, 100 ns, 200 ns, 500ns, 1000ns, 1500ns, customization available)
    3.3 ES620-MPLEx Manual Pulse Width Extremal Change Option
    ESD Injection and IV-Curve Measurement Options
    4.1 ES62X-DBLM TLP Automatic Test Software with PC
    4.2 ES62X-A1 TLP IV-Curve Test Essential Accessories
    4.3 ES62X-BSA Board Level Standard TLP Test Accessories
    4.4 ES62X-BVA Board Level VF-TLP Test Accessories
    4.5 ES62X-BBA Board Level SOA Test Additional Accessories for one channel bias
    4.6 ES62X-A2 Wafer Level TLP Setup Essential Test Accessories
    4.7 ES62X-WSA Wafer Level Standard TLP Test Accessories
    4.8 ES62X-WVA Wafer Level VF-TLP Test Accessories
    4.9 ES62X-WBA Wafer Level SOA Test Additional Accessories for one channel bias
    4.10 CMPS-200A Compact Manual Probe Station with Trinocular Stereo Microscope

     

    (Othe probe stations are available upon request)

    External Pulse Module and measurement Options 
     

     

    5.1

     

     

    ES62X-HBM2

    Human Body Model (HBM) 2-pin Pulse Module:
    HBM-2: 2kV HBM module, Pairing ES622-20 & ES622-25
    HBM-4: 4kV HBM module, Pairing ES622-40 & ES622-50
    HBM-8: 8kV HBM module, Pairing ES622-80 & ES622-100
     

     

    5.2

     

     

    ES62X-HMM2

    Human Metal Model (HMM) 2-pin Pulse Module:
    HMM-6: 6kV HMM module, Pairing ES622-20 & ES622-25
    HMM-12: 12kV HMM module, Pairing ES622-40 & ES622-50
    HMM-24: 24kV HMM module, Pairing ES622-80 & ES622-100
    5.3 ES62X-MM2 Metal Model (MM) 2-pin Pulse Module:
    MM-2: 2kV MM module
    5.4 HBM-BA1 HBM Board Level Test Accessories
    5.5 MM-BA1 MM Board Level Test Accessories
    5.6 TLP based-HMM-BA1 TLP based HMM Board Level Test Accessories
    5.7 TLP based-HMM-WA1 TLP based HMM Wafer Level Test Accessories
    Leakage or DC IV Measurement Options
    6.1 ES62X-SSM System Switch Module (switching between Pulse and DC test)
    6.2 ES62X-STP1 SMU Transient Protector
    Third Party Equipment Paired with TLP System
    7.1 MISC-OSC1 Digital Oscilloscope (1 GHz, 5 Gs, 4 Ch) (Recommended for standard TLP test)
    7.2 MISC-OSC6 Digital Oscilloscope (6 GHz, 20 Gs, 4 Ch) (Recommended for VF-TLP test)
    7.3 KSMU2401 Keithley 2401, 20V, 1A, 1pA/100nV, 20W, 1 Channel
    7.4 KSMU2450 Keithley 2450, 200V, 1A, 10fA/10nV, 20W, 1 Channel
    7.5 KSMU2400 Keithley 2400, 20V, 1A, 1pA/100nV, 20W, 1 Channel
    7.6 KSMU2410 Keithley 2410, 1100V, 1A, 1pA/100nV, 20W, 1 Channel
    7.7 KSMU2602B Keithley 2602B, 40V, 3A, 100fA/100nV, 40W, 2 Channel
    7.8 KSMU2635B Keithley 2635B, 200V, 10A, 0.1fA/100nV, 200W, 2 Channel
    7.9 KSMUB2902A Keithley B2902A, 210V, 10.5A, 10fA/100nV, 31.8W, 2 Channel
    7.10 KPI2230-30-1 Keithley 2230-30-1 3-Channel Programmable DC Power Supply

    ES622 Series TLP Pulsed IV-Curve SystemMany customized specifications are available upon request.

     

    會員登錄

    ×

    請輸入賬號

    請輸入密碼

    =

    請輸驗證碼

    收藏該商鋪

    X
    該信息已收藏!
    標簽:
    保存成功

    (空格分隔,最多3個,單個標簽最多10個字符)

    常用:

    提示

    X
    您的留言已提交成功!我們將在第一時間回復您~
    撥打電話