亚洲欧美日韩精品,日本一区二区在线免费观看,全部无卡免费的毛片在线看,狠狠操av,成人国内精品久久久久影院,夜夜干夜夜,中文字幕人妻丝袜乱一区三区,国产ts在线视频专区
    湖南格雷柏電子科技有限公司
    中級會員 | 第4年

    18573116298

    當前位置:湖南格雷柏電子科技有限公司>>器件級靜電放電解決方案>>CDM充電器件模型測試機>> ES640 Charged Device Model (CDM) Test System

    ES640 Charged Device Model (CDM) Test System

    參  考  價面議
    具體成交價以合同協議為準

    產品型號

    品       牌ESDEMC

    廠商性質代理商

    所  在  地長沙市

    更新時間:2024-08-21 11:16:00瀏覽次數:926次

    聯系我時,請告知來自 化工儀器網
    應用領域 電子/電池,航空航天,汽車及零部件,電氣
    ES640 Charged Device Model (CDM) Test System
    Charged Device Model (CDM) electrostatic discharge is a common cause of microelectronic circuit failure.

    ES640 Charged Device Model (CDM) Test System

    1.    Introduction

    Charged Device Model (CDM) electrostatic discharge is a common cause of microelectronic circuit failure. Sensitive devices can be seriously damaged or destroyed by a CDM discharge at relatively low voltage. This often occurs when the static charged device contacts a metal surface at a different potential. Such an electrostatic discharge often has an extremely fast rise time.

    The Model ES640 is a robotic CDM (Charged Device Model) tester designed to meet all popular CDM ESD test methods, allowing both field induced air discharge methods (FICDM) and relay based contact discharge methods (LI-CCDM, CC-TLP, RP-CCDM). The system includes a computer, environment-controlled chamber, precision XYZ motion system, different types of CDM tester modules, and an automated test and data analysis software.

    Here is a comparison between ESDEMC ES640 CDM Solution to others, including Thermo Scientific Orion3 CDM tester .

    2.    Features

    • High resolution cameras (up to 3) allow for easy pin alignment operation

    • High resolution motion control system (down to 1 µm step)

    • Allows multiple devices being tested in a batch

    • Patent-pending CCDM method allows better repeatability

    • Airtight environment chamber increases drying unit efficiency

    • Support regenerative drying unit (no need of nitrogen)

    3.    Applications

    • General charged device model (CDM) system for package and wafer level tests

    • Support many popular latest CDM methods:

      • ANSI/ESDA/JEDEC JS-002 (FICDM)

      • AEC Q100-011 Rev-D (2019 Ver. follows JS-002)

      • AEC Q101-005 Rev-A (2019 Ver. follows JS-002)

      • ANSI/ESD SP5.3.3 (LI-CCDM, vf-TLP required)

      • CC-TLP (ESDA SP pending, vf-TLP required)

      • Patent pending RP-CCDM method

      • Legacy and customized solutions available upon request

    • Customizable dimension for robotic CBM (Charged Board Model) and flat panel ESD test

    4.    Specifications

     

    Parameters ES640-150 ES640-300 Units Comments
    Max XY Motion Area ≥ 150 X 150 ≥ 300 X 300 mm Probe motion area, customizable
    Max DUT Area 160 X 160 375 X 425 mm MAX Field plate area for DUT
    Field Plate Area 210 X 210 395 X 470 mm Field plate area
    Z Travel ≥ 50 mm  
    Min X, Y, Z Step Size 100 nm  
    Reposition Repeatability ≤ ±6 μm  
    Test Voltage Range ±1 to 2000 or 4000 V Default 2000V, customizable
    Test Voltage Step 1 V  
    Test Voltage Accuracy ± 1% ± 0.1V %  V  
    XY Vision Resolution 1920 X 1080 Pixel  
    Vertical Vision Resolution 2592 X 1944 Pixel  
    Operating Temperature 10 to 40 (°C)  
    Operating Humidity (RH) 0 to 80 %  
    Power 120-240 VAC, 50/60 Hz VAC  
    N2 or CDA Pressure 10 – 120 PSI  
    N2 or CDA Peak Usage 0.2 cfm (or 0.34 m3h)
    300 N2 Tank Avg Usage ~ 19 hour Continuous @ 40RH environment
    Desiccant Avg Usage ~ 24 hour Continuous @ 40RH environment

     

    5.    Ordering Information

    ES640 Charged Device Model (CDM) Test System

    Line Part # or Option # Description
    ES640 Charged Device Model (CDM) Test System
    1.1 ES640-150 Universal CDM platform, 150 X 150 mm Test Area, 2 kV
    1.2 ES640-300 Universal CDM platform, 300 X 300 mm Test Area, 2 kV
    1.3 ES640-HC Humidity Conditioning Unit for Air Discharge Methods
    (Uses reusable desiccants, lower cost of usage than N2 or CDA)
    1.4 ES640-CV4 Charge Voltage Upgrade from 2kV to 4 kV
    ANSI/ESDA/JEDEC JS-002 Standard Related Test Solution (Followed standards include AEC_Q100-011D, AEC_Q101-005A)
    2.1 ES640-JS002 JS-002 Solution – System Integration Package (Including One ES640-JS002-1 Test Fixture)
    2.2 ES640-JS002-C JS002/C101 Calibration Disc (6.8 pF and 55 pF)
    2.3 ES640-JS002-1 JS-002 Test Fixture #1 (Discharge Tip 250 µm, body diameter 350 µm)
    2.4 ES640-JS002-2 JS-002 Test Fixture #2 (Discharge Tip 120 µm, body diameter 200 µm)
    ANSI/ESD S5.3.1-2009 Standard Related Solution (Not recommend for new designs)
    3.1 ES640-S09-F ANSI/ESD S5.3.1-2009_FI-CDM Discharge Unit
    3.2 ES640-S09-D ANSI/ESD S5.3.1-2009_D-CDM Discharge Unit
    3.3 ES640-S09-C ANSI/ESD FR4 Calibration Module (4 and 30 pF)
    3.4 ES640-J13 JEDEC-JESD22-C101F-2013 FI-CDM Discharge Unit
    RP-CCDM Contact First CDM Solutions (New methods for discharge stability improvements, not standardized yet)
    4.1 ES640-RPCCDM ESDEMC Patented Contact First CDM Solution

     

    (Very repeatable contact first method, meets JS002 requirement, not require VF-TLP)

    (Including one ES640-PRCCDM-P1 Discharge Unit)

    4.2 ES640-RPCCDM-P1 RP-CCDM Discharge Unit for Packaged Device
    4.3 ES640-RPCCDM-W1 RP-CCDM Discharge Unit for Bare-die & Wafer Device
    LI-CCDM Contact First CDM solution
    5.1 ES640-LICCDM LI-CCDM Discharge Solution – System Integration Package
    (Including one ES640-LICCDM -P1 Discharge unit, require VF-TLP)
    5.2 ES640-LICCDM-P1 LI-CCDM Discharge Unit for Packaged Device
    5.3 ES640-LICCDM-W1 LI-CCDM Discharge Unit for Bare-die & Wafer Device
    5.4 ES640-vfTLP VF-TLP module for CC-TLP or LI-CCDM Method
    (This VF-TLP module is a compact VF-TLP for the ES640 system. The default configuration is 1 rise-time + 1 pulse-width with limited expansion capability. If more pulse shape options are needed, model ES622 TLP/VF-TLP is the best option)
    CC-TLP Solution
    6.1 ES640-CCTLP CC-TLP Solution – System Integration Package
    (Including 1 set of ES640-CCTLP-1-50 & calibration gauge)
    6.2 CC-TLP-1-50 CC-TLP Discharge Unit with 50m OD GND Plate
    6.3 CC-TLP-1-100 CC-TLP Discharge Unit with 100m OD GND Plate
    6.4 CC-TLP-1-Cal CC-TLP calibration gauge for needle height
    Third Party Instruments for CDM System
    7.1 MISC-OSC2G Digital Oscilloscope (2 GHz, 20 Gs)
    7.2 MISC-OSC6G Digital Oscilloscope (6 GHz, 20 Gs) 

    ES640 Charged Device Model (CDM) Test System

     

     

     